Circulating Fluidized Bed Boiler

  • Description
Product Detail

    Wuxi Zozen Boilers Co., Ltd is one of the best boiler manufacturers and suppliers inChina, producing environmental and energy-saving products. If you need our boiler products or services, please feel free to contact us. We also like to set up partnership if you are capable and interested for cooperation. 


    Circulation Fluidized Bed Boiler (CFB Boiler)

    ? Boiler parameter range:

    DHX10~100t/h Industry circulation fluidized bed boiler, QXF29~168MW circulation fluidized bed boiler

    ? Technical characteristics:

    DHX circulation fluidized bed boiler has the range from low to high pressure, choosing the circulation fluidized bed firing technology. It has the remarkable effect on energy conservation and can suitable to various types of coal, especially to the low quality coal, the dealt biomass, waste slag and activated sludge. 

    QXF series circulation fluidized bed hot water boiler chooses the horizontal single drum, forced circulation, furnace with fully membrane water cooling wall suspended structure, high temperature cyclone separator and fully steel frame of p arrangement. This type of boiler is stable & safety, high heating efficiency and energy conservation, suitable to the city central heating project.

    ? Technical Specifications of DHX Series Circulation Fluid-bed Saturated Steam Boiler:

    Parameter/Data

    Model

    Model

    Model

    DHX10- 1.25-A

    DHX20-2.5-P

    DHX35-1.6-A

    Rated evaporation capacity

    t/h

    10

    20

    35

    Super heated steam outlet pressure

    Mpa

    1.25

    2.5

    1.6

    Super heated steam
         outlet temperature

    ?

    194

    226

    204

    Water in-feeding temperature

    ?

    105

    105

    105

    Fuel available

    Low quality soft coal,coal gangue,lean coal

    Boiler cylindrical central height level

    mm

    17294

    21125

    25175

    Boiler width
         (distance between columns)

    mm

    4000

    3500

    4200

    Boiler depth
         (distance between columns)

    mm

    7660

    9200

    11000

    Boiler cylinder

    mm

    F1200X20

    F1500X25

    F1500X25

    Number of separators

    2

    1

    1

    Type of separators

    Water cooling cyclone

    Heat isolating cyclone

    Type of feed back device

    Non-mechanical

    Non-mechanical

    Non-mechanical

    Type of cinders cooling device

    Roller type water cooling

    Roller type water cooling

    Roller type water cooling

    Ignition mode

    Ignition above the bed

    Ignition under water cooling air bed

    Parameter/Data

    Model

    Model

    Model

    DHX45-1.6-A

    DHX75-1.6-H

    DHX100-1.6-P

    Rated evaporation capacity

    t/h

    45

    75

    100

    Super heated steam outlet pressure

    Mpa

    1.6

    1.6

    1.6

    Super heated steam
         outlet temperature

    ?

    204

    204

    204

    Water in-feeding temperature

    ?

    105

    105

    105

    Fuel available

    Low quality soft coal, coal gangue, lean coal

    Boiler cylindrical central height level

    mm

    25950

    29050

    33390

    Boiler width
         (distance between columns)

    mm

    4600

    6800

    6800

    Boiler depth
         (distance between columns)

    mm

    11600

    11800

    13700

    Boiler cylinder

    mm

    F1500X25

    F1400X25

    F1500X25

    Number of separators

    1

    2

    2

    Type of separators

    Heat isolating cyclone

    Heat isolating cyclone

    Heat isolating cyclone

    Type of feed back device

    Non-mechanical

    Non-mechanical

    Non-mechanical

    Type of cinders cooling device

    Roller type water cooling

    Roller type water cooling

    Roller type water cooling

    lgnition mode

    Ignition above the bed

    Ignition under water cooling air bed

    ? Technical Specifications of QXF Series Circulation Fluid-bed Hot Water Boiler:

    Parameter/Data

    Model

    Model

    Model

    QXF29-1.6/130/70-H

    QXF46-1.6/130/70-A

    QXF58-1.6/150/90-H

    Rated heat output

    MW

    29

    46

    58

    Rated water outlet pressure

    Mpa

    1.6

    1.6

    1.6

    Rated water outlet Temp.

    ?

    130

    130

    150

    Rated water inlet Temp.

    ?

    70

    70

    90

    Boiler hot water flow rate

    t/h

    415.7

    656

    820

    Fuel available

    Low quality soft coal,coal gangue,lean coal

    Boiler cylindrical central height level

    mm

    25904

    27950

    30720

    Boiler width
         (distance between columns)

    mm

    4650

    6400

    7200

    Boiler depth
         (distance between columns)

    mm

    12000

    11700

    13900

    Boiler cylinder

    mm

    F1200x20

    F1500x20

    F1500x20

    Number of separators

    1

    2

    2

    Type of separators

    Heat isolating cyclone

    Heat isolating cyclone

    Heat isolating cyclone

    Type of feed back device

    Non-mechanical

    Non-mechanical

    Non-mechanical

    Type of cinders cooling device

    Roller type water cooling

    Roller type water cooling

    Roller type water cooling

    lgnition mode

    Ignition under water cooling air bed

    Parameter/Data

    Model

    Model

    Model

    QXF70-1.6/130/70-P

    QXF116-1.6/130/70-A

    QXF168-1.6/130/70- A

    Rated heat output

    MW

    70

    116

    168

    Rated water outlet pressure

    Mpa

    1.6

    1.6

    1.6

    Rated water outlet Temp.

    ?

    130

    130

    130

    Rated water inlet Temp.

    ?

    70

    70

    70

    Boiler hot water flow rate

    t/h

    997

    1602

    2403

    Fuel available

    Low quality soft coal, coal gangue, lean coal

    Boiler cylindrical central height level

    mm

    31890

    38350

    45500

    Boiler width
         (distance between columns)

    mm

    6800

    9700

    23000

    Boiler depth
         (distance between columns)

    mm

    14100

    19680

    22100

    Boiler cylinder

    mm

    F1500x20

    F1500x20

    F1500x20

    Number of separators

    2

    2

    2

    Type of separators

    Heat isolating cyclone

    Heat isolating cyclone

    Heat isolating cyclone

    Type of feed back device

    Non-mechanical

    Non-mechanical

    Non-mechanical

    Type of cinders cooling device

    Roller type water cooling

    Roller type water cooling

    Roller type water cooling

    Ignition  mode

    Ignition under water cooling air bed